Chinese Journal of Ultrasonography ; (12): 48-53, 2021.
Article in Chinese | WPRIM | ID: wpr-884284

ABSTRACT

Objective:To investigate the contrast-enhanced ultrasound (CEUS) features of inflammatory hepatocellular adenoma (I-HCA).Methods:The contrast-enhanced ultrasound features I-HCA of 28 cases from April 2009 to November 2019 in Zhongshan Hospital, Fudan University were retrospectively analyzed, including arterial phase enhancement pattern, the homogeneity of enhancement, subcapsular enhancement, and the internal perfusion defect. All I-HCA lesions were divided into >5 cm group( n=9) and ≤5 cm group( n=19), the CEUS features between the two groups were compared. Results:All I-HCA lesions were hyper-enhanced in the arterial phase, among which 39.3% (11/28) showed diffuse filling, 39.3%(11/28) showed centripetal filling, and 21.4%(6/28) showed centrifugal filling pattern. Twenty-five percent (7/28) of I-HCAs showed heterogeneous enhancement, 10.7% (3/28) revealed unenhanced areas within the lesions. Subcapsular vessels were observed in 67.7 (21/31) of I-HCA lesions. Heterogeneous enhancement and unenhanced areas were more frequently detected in lesions >5 cm ( P=0.020, 0.026, respectively), while there was no difference in the enhancement pattern and subcapsular vessels between the two groups ( P>0.05). Inportal venous phase, 42.9%(12/28) of I-HCAs showed hypo-enhancement, and 57.1%(16/28) of lesions showed washout in late phase. According to "hyper-enhancement in arterial phase, sustained hyper- or iso-enhancement in portal venous and late phase" by CEUS, the diagnostic accuracy of benign lesion was 42.9%(12/28). According to any of hyper-enhancement pattern in arterial phase, subcapsular vascular enhancement, and sustained hyper- or iso-enhancement in portal venous and late phase, the diagnostic accuracy of I-HCA was 71.4% (20/28). Conclusions:CEUS is valuable in the diagnosis of inflammatory hepatocellular adenoma.

2.
Chinese Journal of Ultrasonography ; (12): 66-69, 2020.
Article in Chinese | WPRIM | ID: wpr-867978

ABSTRACT

Objective:To investigate the current basic situation of ultrasound machines of ultrasound departments in Shanghai medical institutions, and to provide the basis for making management policy in order to promote medical quality.Methods:Questionnaire surveys about ultrasound machines and service ability including producing countries of ultrasound machines, the number of ultrasound machines, using years of ultrasound machines, yearly workload and the yearly number of patients that each ultrasound machine accepted were made in 2013 and 2018, respectively. Statistical results were compared between the two surveys.Results:Compared with 2013, the share of imported ultrasound machines declined in 2018 (82% vs 91%). Compared with 2013, the number of ultrasound machines in Shanghai medical institutions had increased by 31% in 2018 (2 123 vs 1 617). The occupancy rate of ultrasound machines in tertiary hospitals was the highest (tertiary hospitals 40%, secondary hospitals 25%, primary grade hospitals 20%, and private hospitals 15%). Compared with 2013, the proportion of ultrasound machines that have been used for more than 10 years increased (9% vs 4%), the yearly workload of ultrasound examination had increased by 46% (19.82 million person-time vs 13.59 million person-time). Tertiary hospitals bored the highest proportion of the workload (tertiary hospitals 51%, secondary hospitals 35%, primary grade hospitals 4%, and private hospitals 10%). Currently, the number of ultrasound machines per 10, 000 people in Shanghai was 1.14. The yearly number of patients that each ultrasound machine accepted had increased by 11% (9300 person-time vs 8400 person-time in 2018).Conclusions:The scale of ultrasound departments in Shanghai medical institutions has been developing. Brand localization of ultrasound machines is improving. However, the renewal ability of ultrasound machines still needs to be improved. The workload of ultrasound department is getting heavier. Hierarchical diagnosis and treatment is unbalanced.

3.
Chinese Journal of Ultrasonography ; (12): 66-69, 2020.
Article in Chinese | WPRIM | ID: wpr-799090

ABSTRACT

Objective@#To investigate the current basic situation of ultrasound machines of ultrasound departments in Shanghai medical institutions, and to provide the basis for making management policy in order to promote medical quality.@*Methods@#Questionnaire surveys about ultrasound machines and service ability including producing countries of ultrasound machines, the number of ultrasound machines, using years of ultrasound machines, yearly workload and the yearly number of patients that each ultrasound machine accepted were made in 2013 and 2018, respectively. Statistical results were compared between the two surveys.@*Results@#Compared with 2013, the share of imported ultrasound machines declined in 2018 (82% vs 91%). Compared with 2013, the number of ultrasound machines in Shanghai medical institutions had increased by 31% in 2018 (2 123 vs 1 617). The occupancy rate of ultrasound machines in tertiary hospitals was the highest (tertiary hospitals 40%, secondary hospitals 25%, primary grade hospitals 20%, and private hospitals 15%). Compared with 2013, the proportion of ultrasound machines that have been used for more than 10 years increased (9% vs 4%), the yearly workload of ultrasound examination had increased by 46% (19.82 million person-time vs 13.59 million person-time). Tertiary hospitals bored the highest proportion of the workload (tertiary hospitals 51%, secondary hospitals 35%, primary grade hospitals 4%, and private hospitals 10%). Currently, the number of ultrasound machines per 10, 000 people in Shanghai was 1.14. The yearly number of patients that each ultrasound machine accepted had increased by 11% (9300 person-time vs 8400 person-time in 2018).@*Conclusions@#The scale of ultrasound departments in Shanghai medical institutions has been developing. Brand localization of ultrasound machines is improving. However, the renewal ability of ultrasound machines still needs to be improved. The workload of ultrasound department is getting heavier. Hierarchical diagnosis and treatment is unbalanced.

4.
Chinese Journal of Hospital Administration ; (12): 77-80, 2020.
Article in Chinese | WPRIM | ID: wpr-798680

ABSTRACT

Objective@#To investigate the current basic situation of the staff of ultrasound departments in Shanghai′s medical institutions, for providing references in making management policy of these professionals.@*Methods@#Questionnaire surveys on human resource and service ability were made to all the ultrasound departments of medical institutions in Shanghai in December 2013 and November 2018 respectively. Data of the two surveys were compared and analyzed, and were descriptively analyzed by mean and percentage.@*Results@#The number of ultrasound professionals per 10 000 people in Shanghai was 1.04 in 2018. Tertiary hospitals had advantages in the number of the professionals, and the proportion of professional qualification, age, education background and professional title of the professionals. Compared to those data in 2013, the number of ultrasound professionals had increased 31.8% in 2018. The proportion of medical practitioners with medical imaging specialty was 95.6%(2 063/2 158), and had increased by 4.7 percent. The medical services workload of ultrasound was 19.82 million person-time, and had increased 45.8%.@*Conclusions@#Development of ultrasound departments was rapid, but the development of professionals was unbalanced with the development of medical services. It is suggested to strengthen training of ultrasound professionals and improve the system of hierarchical medical system.

5.
Chinese Journal of Hospital Administration ; (12): 77-80, 2020.
Article in Chinese | WPRIM | ID: wpr-872195

ABSTRACT

Objective:To investigate the current basic situation of the staff of ultrasound departments in Shanghai′s medical institutions, for providing references in making management policy of these professionals.Methods:Questionnaire surveys on human resource and service ability were made to all the ultrasound departments of medical institutions in Shanghai in December 2013 and November 2018 respectively. Data of the two surveys were compared and analyzed, and were descriptively analyzed by mean and percentage.Results:The number of ultrasound professionals per 10 000 people in Shanghai was 1.04 in 2018. Tertiary hospitals had advantages in the number of the professionals, and the proportion of professional qualification, age, education background and professional title of the professionals. Compared to those data in 2013, the number of ultrasound professionals had increased 31.8% in 2018. The proportion of medical practitioners with medical imaging specialty was 95.6%(2 063/2 158), and had increased by 4.7 percent. The medical services workload of ultrasound was 19.82 million person-time, and had increased 45.8%.Conclusions:Development of ultrasound departments was rapid, but the development of professionals was unbalanced with the development of medical services. It is suggested to strengthen training of ultrasound professionals and improve the system of hierarchical medical system.

6.
Chinese Journal of Ultrasonography ; (12): 529-534, 2018.
Article in Chinese | WPRIM | ID: wpr-806759

ABSTRACT

Objective@#To evaluate the feasibility of quantitative analysis of dynamic 3-dimensional contrast-enhanced ultrasound (3D-CEUS) for treatment effects of microwave coagulation on xenograft tumors in nude mice.@*Methods@#BALB/c nude mice transplanted of HepG2 cells were divided into treatment group(n=16) and control group(n=16). The tumors were treated by incomplete microwave coagulation in the treatment group when their maximum diameters were about 0.8~1.0 cm. The baseline ultrasound and dynamic 3D-CEUS were performed on 1 d before treatment, 3 d after treatment, 7 d after treatment and 14 d after treatment. Time-intensity curves of the tumors were obtained by fitting. The quantitative parameters were also obtained, including peak intensity (PI), time to peak (TTP), mean transit time (MTT), slope (S), area under the curve (AUC), area under the curve of wash-in (AWI), and area under the curve of wash-out (AWO).@*Results@#There were significant differences(P=0.029) between the two groups in PI, S, AUC, AWO on 3 d and 14 d. The differences in other parameters were not statistically significant (P>0.05). On 1 d before treatment and 7 d after treatment, none of the parameters had statistically significant difference (P>0.05).@*Conclusions@#The quantitative analysis of dynamic 3D-CEUS is feasible to assess the treatment response on xenograft tumors in nude mice.

7.
Chinese Journal of Ultrasonography ; (12): 397-400, 2018.
Article in Chinese | WPRIM | ID: wpr-707687

ABSTRACT

Objective To evaluate the correlation and consistency of dynamic three-dimensional contrast-enhanced ultrasonography ( 3D-CEUS ) and two-dimensional contrast-enhanced ultrasonography (2D-CEUS) in the time-intensity curve ( TIC) parameters of quantitative analysis in liver neoplasms. Methods Thirty patients were examined with 2D-CEUS and dynamic 3D-CEUS.The dynamic raw data were analyzed by quantitative analysis software. The regions of interest were manually selected around the entire lesion;TIC curves were generated and fitted respectively. Quality of fit ( QOF) was used to evaluate the degree of fit between the fitted curve and the initial ccoefficients of S,PI and AUC were 0.92,0.72 and urve. The corresponding 2D-CEUS and 3D-CEUS quantitative parameters of the same lesion were compared,including peak intensity ( PI),slope ( S),area under curve (AUC),time to peak (TTP) and mean transit time (MTT). The correlation of the intensity-related quantitative parameters and the consistency of the time-related quantitative parameters were analyzed between the two kinds of CEUS. Results The consistency of time related quantitative parameters,including MTT and TTP,were 0.97 and 0.96,and the correlation were 0.94 and 0.93. The correlation 0.65,respectively. Conclusions The quantitative results of 3D-CEUS are stable and reliable,and have fair concordance with 2D-CEUS. Dynamic 3D-CEUS can be used for clinical evaluation of the blood perfusion of liver neoplasms.

8.
Chinese Journal of Ultrasonography ; (12): 211-214, 2018.
Article in Chinese | WPRIM | ID: wpr-707656

ABSTRACT

Objective To evaluate the imaging features of hepatic epithelioid angiomyolipoma (EAML) on contrast-enhanced ultrasound (CEUS). Methods The imaging features of pathologically proved hepatic EAML lesions in 17 patients who had undergone baseline ultrasound and CEUS examinations were evaluated retrospectively. Results All of the cases were single lesion.70.6% (12/17) of the lesions were hypoechoic on ultrasound and 82.4% (14/17) of the lesions were heterogeneous.Flow signals were detected in 88.2% (15/17) of the lesions and 82.4% (14/17) of the lesions showed ringlike or arc arterials peripherally on color Doppler flow imaging (CDFI).The value of RI was 0.38-0.56.On CEUS,all lesions exhibited remarkable hyperenhancement in the arterial phase. 29.4% (5/17) of the lesions showed branched enhancement,70.6% (12/17) of the lesions showed diffusely entire enhancement.Strong ring-like enhancement peripherally was detected in 29.4% (5/17) of the lesions.88.2% (15/17) of the lesions were detected homogeneously enhancement during the peak period on CEUS. Washout of contrast agent and hypoechogenicity to surrounding liver tissue during portal or late phase were observed in 41.2% (7/17) and 64.7% (11/17) of the cases retrospectively.Conclusions The combination of real-time CEUS and baseline US can improve the correct diagnosis of hepatic EAML.

9.
Chinese Journal of Ultrasonography ; (12): 1042-1047, 2018.
Article in Chinese | WPRIM | ID: wpr-734217

ABSTRACT

Objective To investigate the imaging features of dysplastic nodules with a focus of hepatocellular carcinoma ( DN-HCC ) on contrast-enhanced ultrasound ( CEUS ) and to improve the diagnostic accuracy . Methods The clinical data of 60 patients and CEUS imaging of 62 hepatic nodules [DN-HCCs , n =54 ;dysplastic nodules (DN) , n =8] pathologically proved were reviewed retrospectively . According to Contrast Enhanced Ultrasound Liver Imaging Reporting and Data System (CEUS LI-RADS) , the lesions were categorized . Results Significantly different CEUS patterns between DN-HCCs and DNs were observed ( P < 0 .05) . During the arterial phase ,54 DN-HCC lesions showed various enhancement patterns [ hypervascular ,59 .3% ( 32/54 ) ;nodule-in-nodule ,9 .3% ( 5/54 ) ;isovascular ,13 .0% ( 7/54 ) and hypovascular ,18 .5% (10/54)] . Of the 54 DN-HCC lesions ,44 .4% (24/54) showed washout during the late phase .Of the 8 DN lesions ,62 .5% (5/8) showed iso-enhancement during the arterial phase ,25% (2/8) showed hypo-enhancement ,and 12 .5% (1/8) showed hyper-enhancement . No DN lesion showed washout during the late phase .According to CEUS LI-RADS (LR) algorithm ,27 .8% (15/54) DN-HCCs were LR-5 ,46 .3% (25/54) DN-HCCs were LR-4 ,25 .9% (14/54) DN-HCCs and 100% (8/8) DNs were LR-3 . Regarding hyper-enhancement ( including local hyper-enhancement ) during the arterial phase or hypo-enhancement (including local hypo-enhancement) during the late phase as the diagnostic standard of DN-HCC , the diagnostic sensitivity , specificity and accuracy value were 83 .3% , 87 .5% and 83 .9% , respectively . Conclusions The imaging features of hyper-enhancement during the arterial phase or hypo-enhancement during the late phase on CEUS are useful to diagnose DN-HCCs .

10.
Chinese Journal of Ultrasonography ; (12): 687-690, 2012.
Article in Chinese | WPRIM | ID: wpr-427629

ABSTRACT

Objective To compare and analyze the similarities and differences of the blood perfusion characteristics of the renal pelvic carcinoma displayed by contrast-enhanced ultrasonography(CEUS) and contrast-enhanced computed tomography(CECT).Methods The characteristics of CEUS and CECT were anzlyzed retrospectively in 40 confirmed renal pelvic carcinoma cases by operation and pathology.The modality and phases of enhancement,including wash-in and washout time,as well as the perfusion appearances,were observed by CEUS and CECT.Results CEUS detected the cortical phase enhancement in all renal pelvic tumors,including synchronously enhancement in 14 tumors and delayed enhancement in 26 tumors.At peak times,hypoechogenicity compared to the normal renal cortex was shown in 31 tumors,hyperechogenicity in 4 tumors and isoechogenicity in 5 tumors.Fast wash-out in medulla phase was displayed in 35 tumors,isochronously wash-out in 2 tumors and delayed wash-out in 3 tumors.The minimum diameter in 40 renal pelvic tumors was 1.5 cm.CECT showed the enhancement in 38 tumors,mostly mild to moderate homogeneous enhancement,and enhancement was lower than the surrounding renal parenchyma.The diagnostic accuracy of CEUS was 77.5% (31/40),and the diagnostic accuracy of CECT was 82.5 % (33/40).The difference was not statistically significant between CEUS and CECT ( P >0.05).Conclusions CEUS and CECT have higher diagnostic accuracy of the renal pelvic carcinoma,so the joint detection can increase the detection rate of early diagnosis of the renal pelvic carcinoma.

11.
Chinese Journal of Ultrasonography ; (12): 312-315, 2012.
Article in Chinese | WPRIM | ID: wpr-418715

ABSTRACT

Objective To investigate the value of quantitative analysis in the diagnosis of renal lesions with contrast-enhanced ultrasound.Methods Sixty cases with renal lesions confirmed by surgery and pathology underwent contrast-enhanced ultrasound preoperatively and quantitative analysis retrospectively.The Sonoliver software was applied in the analysis of CEUS imaging and in the recoustruction of quantitative parameter,s.Five parameters were calculated,including the maximum intensity (IMAX),rise time (RT),time to peak (TTP),mean transit time (mTT) and area under the curve (AUC).Results There were statistically differences in parameters RT,mTT and AUC ( P < 0.05) and significant differences in parameter IMAX ( P <0.01).In malignant tumors,the RT and mTT were less than that of the benign while IMAX and AUC were more than that of the benign.Conclusions Contrast-enhanced ultrasound using a quantitative parametric analysis offers more information and is a promising tool in the diagnosis and differentiation of renal masses.

12.
Chinese Journal of Ultrasonography ; (12): 30-33, 2011.
Article in Chinese | WPRIM | ID: wpr-384436

ABSTRACT

Objective To evaluate the value of contrast-enhanced ultrasonography (CEUS) in quantitative diagnosis of chronic kidney dysfunction(CKD) by comparing it with color Doppler imaging (CDFI). Methods Tirty-three cases (15 males and 18 females) of clinical confirmed CKD (stage Ⅲ~Ⅴ)were included. Forty-five healthy volunteers were performed as control group. CEUS and CDFI were performed on each patient. After intravenous bolus injection of 1ml SonoVue each side,CEUS of renal cortex blood perfusion was collected successively,and a time-intensity curve(TIC) was created with Philips iU22 system's QLAB software. Resistance index(RI) and peak systolic velocity(PSV) of renal partial arteries were also tested. Results Compared with normal kidney,CKD patients had delayed perfusion and decreased intensity. Changes of area under curve(AUC), derived peak intensity(DPI), slope rate of ascending curve(A)and time to peak(TTP) were statistically significant ( P <0. 05). Sensitivities of AUC,DPI,A and TTP in diagnosis of CKD (stage Ⅲ~Ⅴ ) were 91.2% ,84. 9% ,90.9% and 85.3%, their specificities were 95.4%,88.9% ,93.3% and 90.9%, their accuracies were 93.6%, 87. 2%, 92.3% and 88. 5%, respectively. The results of CEUS were better than RI in CDFI (sensitivity 70.4%, specificity 37. 8%, accuracy 52.2%).Conclusions CEUS can precisely display the hemodynamic change in CKD ( stage Ⅲ~Ⅴ ), and is more sensitive than CDFI.

13.
Chinese Journal of Ultrasonography ; (12): 216-218, 2011.
Article in Chinese | WPRIM | ID: wpr-414108

ABSTRACT

Objective To evaluate contrast-enhanced ultrasound imaging of carotid atherosclerosis with different stenostic degree as a clinical tool to study intraplaque neovascularization.Methods Fifty-eight patients suspected of carotid stenosis with 73 plaques were studied by standard and contrast-enhanced ultrasound.Plaque echogenicity at standard ultrasound were evaluated.Contrast enhancement within the plaques was categorized as 0 - 4 degree and compared to the stenosis degree and the plaque echogenicity.The degree of stenosis was determined by intravenous digital subtraction angiography.Results In the group with stenosis less than 90% ,stenosis degree was not associated with the grade of contrast enhancement (P =0.358),while the grade of enhancement was significantly higher in the group with sever stenosis(>90%).The grades of enhancement were significantly different between plaques with different echogenicity (P =0.000).Conclusions Contrast-enhanced real-time ultrasound imaging can demonstrate the enhancement of carotid plaques non-invasively,which is helpful for assessing intraplaque neovascularization and provide valuable information for plaque risk stratification

14.
Chinese Journal of Ultrasonography ; (12): 245-248, 2011.
Article in Chinese | WPRIM | ID: wpr-414100

ABSTRACT

Objective To explore the diagnostic value of contrast-enhanced ultrasonography (CEUS) in ureteral lesions.Methods The ultrasonogram of conventional ultrasound and CEUS were retrospectively analyzed in 19 confirmed ureteral lesions cases by operation and pathology.The size,inner echoes,boundary and color blood signal of ureteral lesions were observed by conventional ultrasound.The modality and phases of enhancement,including arrival time,peak time,washout time and appearance of internal structure,were observed by CEUS.Results The 19 ureteral tumors were of maximum widths between 2.1 to 7.7 cm.Conventional ultrasound showed 7 hypoechoic masses,10 isoechoic masses,1 hyperechoic mass and 1 unclear mass.Color Doppler flow imaging showed fairly rich blood signal in 8 tumors,a small amount of blood signal around tumor in 6 tumors and no blood signal in the rest.In early phase,CEUS showed enhancement in all 19 ureteral lesions,including synchronously enhancement in 8 tumors and delayed enhancement in 11 tumors.In peak time,hypoechogenicity compared to the normal renal cortex was shown in 3 tumors,hyperechogenicity in 11 tumors and isoechogenicity in 5 tumors.In late phase,fast wash-out was displayed in 16 tumors,isochronously wash-out in 1 tumor,delayed wash-out in 1 tumor and unclear in 1 tumor.The detection rates of blood supply and clear boundary in ureteral lesions and the diagnostic sensitivity for ureteral cancer were 74% (14/19),16% (3/19),50% (8/16) by conventional ultrasound respectively.The detection rates of blood supply and clear boundary in ureteral lesions and the diagnostic sensitivity for ureteral cancer were 100% (19/19) ,58% (11/19) ,94% (15/16) by CEUS respectively.The change of these performances was statistically significant between conventional ultrasound and CEUS.Conclusions CEUS can improve blood supply,boundary and the diagnostic sensitivity of ureteral lesions.

15.
Chinese Journal of Ultrasonography ; (12): 21-24, 2010.
Article in Chinese | WPRIM | ID: wpr-391348

ABSTRACT

Objective To investigate enhancement appearance of hepatic focal nodular hyperplasia(FNH) at real-time gray-scale contrast enhanced ultrasonography(CEUS),and evaluate the value of CEUS in the diagnosis of FNH. Methods Thirty-four patients (36 lesions) with histologically proved FNH were examined by ultrasonography. Appearance on conventional ultrasonography and the enhancement pattern on CEUS were investigated. Results Thirty-six lesions were mostly hypoechoic.39% (14/36) of lesions had peripheral hypoechogenic circle. Color Doppler flow imaging showed a asteroid-like or spoke-and-wheel pattern in 65% (20/ 31) of lesions.Three enhancement patterns were observed in the early arterial phase: whole-enhancement pattern (28%, 10/36), gushing-spring enhancement pattern (44%, 16/36), and spoke-and-wheel enhancement pattern (28%,10/36).The frequency of central scar on CEUS was 17% (6/36), and detection rate of central scar by CEUS compared with pathology was 40% (6/15).Regarding one of the features (gushing-spring enhancement, spoke-and-wheel enhancement and scar) as standard of FNH, the coincidence of CEUS in this group was 78% (28/ 36) ,which was significantly higher than that of conventional ultrasonography 28% (10/36).Conclusions CEUS can be as a important method for diagnosing FNH.

16.
Chinese Journal of Ultrasonography ; (12): 408-410, 2010.
Article in Chinese | WPRIM | ID: wpr-389600

ABSTRACT

Objective To evaluate the value of quantitative analysis of real-time elastosonography in the differential diagnosis of benign and malignant thyroid nodules. Methods The elastograms of eight-six patients with 98 thyroid nodules were observed. The strain ratio of each lesion and the averages of those of benignancy and malignancy were calculated. With the ROC curve, the critical point of the strain ratio of different lesions was gotten. All the lesions were confirmed with surgery and pathologic examination. Results The average of strain ratio of benign nodules was 2. 18,while that of malignancy was 8. 48. The strain ratio of benign and malignant lesions were of significant difference statistically (P <0.05). According to ROC curve, the critical point of strain ratio between benign and malignant lesions was 3. 3. Conclusions The quantitative analysis of real-time elastosonography is a newly valuable technique of ultrasonography which is helpful in the differential diagnosis of thyroid lesions.

17.
Chinese Journal of Nephrology ; (12): 516-519, 2010.
Article in Chinese | WPRIM | ID: wpr-383138

ABSTRACT

Objective To evaluate the contrast-enhanced ultrasonography (CEUS) in quantitative diagnosis of chronic renal insufficiency. Methods Correlation of CEUS indexes with glomerular filtration rate (GFR) detected by 99mTc-DTPA renography was examined. Thirty-three cases of clinical chronic renal insufficiency were enrolled in the study. They were 15 males and 18 females with average age of (43.33±6.78) years. After intravenous bolus injection of 1 ml SonoVue,CEUS of renal cortex blood perfusion was performed successfully, and a time-intensity curve (TIC)was created with PHILIPS iU22 system's QLAB software. A 148 to 222 MBq dose of 99mTc-DTPA was injected as a bolus from antecubital vein. Renal scintigraphic images were collected immediately and GFR was obtained. Results The significant correlation coefficients between GFR and CEUS quantitative indexes were as follows: rAUC (area under curve)=0.886 (P<0.05), rA (slope rate of ascending curve, A) =0.804(P<0.05). However, rDPI (derived peak intensity, DPI)=0.021 (P>0.05), rTTP (time to peak, TTP) =0.043 (P>0.05), rα (slope rate of descending curve,α)=0.039 (P>0.05). Conclusion CEUS can precisely display the hemodynamic change of chronic renal insufficiency, which is well correlated with GFR by 99mTc-DTPA renography.

18.
Chinese Journal of Ultrasonography ; (12): 717-721, 2009.
Article in Chinese | WPRIM | ID: wpr-393273

ABSTRACT

0.05). Conclusions CEUS can accurately display the perfusion changes of CIRD model of dogs,it's more sensitive than the BUN and SCr. DPI and TTP are the most sensitive quantitative indexes of CEUS.

19.
Chinese Journal of Ultrasonography ; (12): 708-712, 2009.
Article in Chinese | WPRIM | ID: wpr-393028

ABSTRACT

ular perfusion in tumors objectively, which is potential in monitoring tumor vascular response to antiangiogenic therapy.

20.
Chinese Journal of Ultrasonography ; (12): 942-945, 2009.
Article in Chinese | WPRIM | ID: wpr-391985

ABSTRACT

Objective To investigate the correlations between quantitative parameters of contrast-enhanced ultrasonography(CEUS) and histopathological stage of liver fibrosis.Methods Sixty cases of hepatic fibrosis diagnosed pathologically were examined with CEUS.The dynamic images of CEUS were analyzed off-line with a quantitative software.Region of interest (ROI) were drawn separately in hepatic artery(HA),liver parenchyma(PA),main portal vein(PV) and right hepatic vein(HV).The time intensity curve(TIC) and some quantitative parameters,including arrival time,increased signal intensity(ISI),peak intensity(PI) and area under curve(AUC) were acquired.Intrahepatic transit time of contrast agents were calculated as the arrival time difference between hepatic artery(HA) and HV(HA-HVTT),between PV and HV(PV-HVTT) and between PA and HV (PA-HVTT).All the parameters were compared with histopathologic stage.Results All cases were grouped into mild fibrosis (S0 and S1,25 cases),moderate fibrosis (S2 and S3,17 cases) and severe fibrosis (S4,18 cases) according pathologic stage.HA-HVTT,PV-HVTT and PA-HVTT decreased with the development of liver fibrosis.The parameters of ISI,PI and AUC obtained from TIC of portal vein reduced with the progression of fibrosis,too(P<0.05).Receive operating characteristic(ROC) curve analysis showed that the area under curve of HA-HVTT,PV-HVTT and PA-HVTT were 0.808,0.848,and 0.823 (S>S1),and 0.856,0.903,and 0.806 (S>S3),respectively.Conclusions Quantitative parameters of CEUS reflect the stage of liver fibrosis mediately.The parameters of HA-HVTT,PV-HVTT and PA-HVTT are closely correlated with the stage of liver fibrosis.